This paper is only available as a PDF. To read, Please Download here.
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to InjuryAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- An Atlas of Closed Nailing of the Tibia and Femur. Martin Dunitz, London1991
- Current use of the intramedullary nail.in: Leung PC Current Practise of Fracture Treatment. Springer-Verlag, Berlin1994: 119
- Influences of some design parameters on the biomechanics of the unreamed intramedullary nail.J Orthop Trauma. 1993; 7: 311
- Mechanical failures of intramedullary tibial nails applied without reaming.Clin Orthop Rel Res. 1995; 315: 129
- The mechanics of intramedullary nails for femoral fractures.Unfallchirurg. 1990; 93: 499
- Open tibial diaphyseal fractures: Results of unreamed locked intramedullary nailing.Clin Orthop Rel Res. 1995; 315: 114
- Biomechanical analysis of the mechanism of interlocking nail failure.Arch Orthop Trauma Surg. 1992; 111: 268
- L'apport du verouillage dans l'enclouage centromédullaire des os longs.Rev Chir Orthop. 1978; 64: 635
- A new distal aiming device for locking nail fixation.Orthopedics. 1988; 11: 1725
- Fehlerhafte Technik und Komplikationen.Hefte Unfallheilk. 1983; 161: 143
- Reamed or unreamed nailing for closed tibial fractures.J Bone Joint Surg [Br]. 1996; 78B: 580
- Enclouage centro-médullaire claveté.Rev Chir Orthop. 1983; 49: 547
Pennig D. An improved screw design for locked intramedullary nailing. Injury (in press).
- Experimentelle Untersuchungen Über die biomechanischen Eigenschaften von Hohlnageln und Vollnageln zur verriegelbaren Mark-nagelung am Hund.Biomedizinische Technik. 1995; 40: 24
- Analyse implantationsbedingter Nagelverformung und röntgenmorphometrische untersuchungen als Grundlage für ein Zielgerät zur distalen Verriegelung ohne Röntgenbildverstärker.Unfallchirurg. 1996; 99: 671
Gausepohl T, Pennig D and Koebke J. Unpublished data.
- Exposure of the orthopaedic surgeon to radiation.J Bone Joint Surg [Am]. 1993; 75: 326
- Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures.South African Med J. 1992; 81: 312
Article info
Publication history
Accepted:
October 25,
1996
Identification
Copyright
© 1997 Published by Elsevier Inc.