      Abstract

      Introduction

      Careful distal locking screw insertion into the subchondral zone is necessary to obtain proper mechanical strength of unstable distal radius fractures using volar locking plating. However, subchondral zone screw insertion increases the risk of intra-articular screw penetration, which may remain unrecognized during surgery due to complex distal radial anatomy. The purpose of this study was to evaluate the role of fluoroscopic guidance with a 45° supination oblique view technique for placing distal screws into the subchondral zone during volar locking plating for unstable distal radius fractures and to explore the factors associated with poor screw placement.

      Methods

      We retrospectively analyzed 171 wrists of 169 patients treated with variable-angle volar locking plates for unstable radius fractures. The subchondral zone was defined as the metaphyseal area within 4 mm of the articular margin of the distal radius. The location of the distal locking screws and radiographic parameters, including the teardrop angle, were measured using computed tomography scans and X-rays. Clinical and radiographic factors were examined to determine their possible associations with screw placement failure.

      Results

      Of 581 distal screws inserted, 559 screws (96.2%) were inserted into the subchondral zone and 17 screws into the metaphyseal zone (2.9%). Five screws (0.7%) in three wrists showed intra-articular placement: four screws were placed into the lunate fossa and one into the scaphoid fossa. These three wrists also exhibited significantly reduced teardrop angles. The distal screws were significantly closer to the joint line in the lunate fossa than the scaphoid fossa (1.9 ± 0.9 mm vs. 2.8 ± 1 mm, P < 0.000).

      Conclusion

      The 45° supination oblique view technique is a useful fluoroscopic guiding technique for accurate and safe distal screw placement in the subchondral zone in volar locking plate fixation for distal radial fractures. However, a decreased teardrop angle or extended lunate fossa should be corrected before distal screw insertion to avoid intra-articular screw placement.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Injury
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Chung K.C.
        • Shauver M.J.
        • Birkmeyer J.D.
        Trends in the United States in the treatment of distal radial fractures in the elderly.
        J Bone Jt Surg Am Vol. 2009; 91: 1868-1873
        • Drobetz H.
        • Black A.
        • Davies J.
        • Buttner P.
        • Heal C.
        Screw placement is everything: risk factors for loss of reduction with volar locking distal radius plates.
        World J Orthop. 2018; 9: 203-209
        • Drobetz H.
        • Bryant A.L.
        • Pokorny T.
        • Spitaler R.
        • Leixnering M.
        • Jupiter J.B.
        Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction–a biomechanic study in a cadaveric model.
        J Hand Surg Am. 2006; 31: 615-622
        • Bentohami A.
        • de Burlet K.
        • de Korte N.
        • van den Bekerom M.P.
        • Goslings J.C.
        • Schep N.W.
        Complications following volar locking plate fixation for distal radial fractures: a systematic review.
        J Hand Surg Eur Vol. 2014; 39: 745-754
        • Sirnio K.
        • Flinkkila T.
        • Vahakuopus M.
        • Hurskainen A.
        • Ohtonen P.
        • Leppilahti J.
        Risk factors for complications after volar plate fixation of distal radial fractures.
        J Hand Surg Eur Vol. 2019; 44: 456-461
        • Tweet M.L.
        • Calfee R.P.
        • Stern P.J.
        Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius.
        J Hand Surg Am. 2010; 35: 619-627
        • Boyer M.I.
        • Korcek K.J.
        • Gelberman R.H.
        • Gilula L.A.
        • Ditsios K.
        • Evanoff B.A.
        Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation.
        J Hand Surg Am. 2004; 29: 116-122
        • Smith D.W.
        • Henry M.H.
        The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures.
        J Hand Surg Am. 2004; 29: 703-706
        • Soong M.
        • Got C.
        • Katarincic J.
        • Akelman E.
        Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study.
        J Hand Surg Am. 2008; 33: 1720-1723
        • Kaneshiro Y.
        • Hidaka N.
        • Yano K.
        • Kawabata A.
        • Fukuda M.
        • Sasaoka R.
        • et al.
        Intraoperative computed tomography with an integrated navigation system versus freehand technique under fluoroscopy in the treatment of intra-articular distal radius fractures.
        J Plast Surg Hand Surg. 2019; 53: 255-259
        • Kawabata A.
        • Sogabe Y.
        • Morimoto Y.
        • Takamatsu K.
        Volar locking plate fixation for distal radius fractures by intraoperative computed tomographic-guided navigation.
        J Hand Surg Glob Online. 2020; 2: 290-296
        • Orbay J.L.
        • Badia A.
        • Indriago I.R.
        • Infante A.
        • Khouri R.K.
        • Gonzalez E.
        • et al.
        The extended flexor carpi radialis approach: a new perspective for the distal radius fracture.
        Tech Hand Up Extrem Surg. 2001; 5: 204-211
        • Teunis T.
        • Meijer S.
        • Jupiter J.
        The correlation between the teardrop angle and anterior lunate facet displacement in plating distal radial fractures.
        J Hand Surg Eur Vol. 2019; 44: 462-467
        • Hill B.W.
        • Shakir I.
        • Cannada L.K.
        Dorsal screw penetration with the use of volar plating of distal radius fractures: how can you best detect?.
        J Orthop Trauma. 2015; 29: e408-e413
        • Langerhuizen D.W.G.
        • Bergsma M.
        • Selles C.A.
        • Jaarsma R.L.
        • Goslings J.C.
        • Schep N.W.L.
        • et al.
        Diagnosis of dorsal screw penetration after volar plating of a distal radial fracture.
        Bone Joint J. 2020; (102-B:874-80)
        • Ozer K.
        • Wolf J.M.
        • Watkins B.
        • Hak D.J.
        Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius.
        J Hand Surg Am. 2012; 37: 963-967
        • Medoff R.J.
        Essential radiographic evaluation for distal radius fractures.
        Hand Clin. 2005; 21: 279-288
        • MacDermid J.C.
        • Richards R.S.
        • Donner A.
        • Bellamy N.
        • Roth J.H.
        Responsiveness of the short form-36, disability of the arm, shoulder, and hand questionnaire, patient-rated wrist evaluation, and physical impairment measurements in evaluating recovery after a distal radius fracture.
        J Hand Surg Am. 2000; 25: 330-340
        • Diong T.W.
        • Haflah N.H.M.
        • Kassim A.Y.M.
        • Habshi S.
        • Shukur M.H.
        Use of computed tomography in determining the occurrence of dorsal and intra-articular screw penetration in volar locking plate osteosynthesis of distal radius fracture.
        J Hand Surg Asian Pac Vol. 2018; 23: 26-32
        • Ma D.
        • Schick B.
        Subchondral screw placement in volar plate fixation for distal radius fractures: a retrospective observational analysis.
        J Hand Surg Eur Vol. 2021; 46: 92-94
        • Borggrefe J.
        • Bolte H.
        • Worms W.
        • Mahlke L.
        • Seekamp A.
        • Menzdorf L.
        • et al.
        Comparison of intraoperative flat panel imaging and postoperative plain radiography for the detection of intraarticular screw displacement in volar distal radius plate ostheosynthesis.
        Orthop Traumatol Surg Res. 2015; 101: 913-917
        • Knight D.
        • Hajducka C.
        • Will E.
        • McQueen M.
        Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes.
        Injury. 2010; 41: 184-189
        • Pace A.
        • Cresswell T.
        Use of articular wrist views to assess intra-articular screw penetration in surgical fixation of distal radius fractures.
        J Hand Surg Am. 2010; 35: 1015-1018
        • Gyuricza C.
        • Carlson M.G.
        • Weiland A.J.
        • Wolfe S.W.
        • Hotchkiss R.N.
        • Daluiski A.
        Removal of locked volar plates after distal radius fractures.
        J Hand Surg Am. 2011; 36: 982-985