Advertisement
Research Article| Volume 23, SUPPLEMENT 2, S5-S16, 1992

Drill bit failure without implant involvement — an intraoperative complication in orthopaedic surgery

      This paper is only available as a PDF. To read, Please Download here.

      Abstract

      The aetiology, frequency and consequences of drill bit failure during surgical intervention in human and animal bone tissue are investigated and discussed to provide the surgeon confronted with this problem with a scientifically based procedure. The literature on this subject is rather inadequate, i.e. only one publication in the last decade could be found dealing with this topic and this was a veterinary case. The Laboratory for Experimental Surgery in Davos has received several enquiries from the medical profession worldwide as to correct procedure in the case of drill bit failure.
      Three sources of information were investigated in order to furbish a reply to these enquiries, these were the AO/ASIF documentation centre in Berne, a survey of 280 surgeons and orthopedic doctors in Switzerland and a survey of 83 AO/ASIF foundation members. One broken tap (tool steel) was removed two years after the operation and metallographic investigations carried out. A frequency of 3 drill bit failure per 1000 internal fixations (0.3 %) is apparent in nearly all data. The reasons for drill bit failure were investigated. Drill bit failure occurs more frequently in the proximal femur and when using angled plates. On the basis of this enquiry the following guidelines can be offered to the surgeon. A broken drill bit which is not in contact with an implant can be left in the body without any risk of delayed recovery. However, if the drill fragment is situated near a joint or if it can be easily removed without further trauma to the bone, then it should be removed.
      Once the fracture has healed the broken drill bit should be removed along with the implant provided no exceptional difficulties are involved.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Injury
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • AO/ASIF Foundation Information booklet
        Research, development, education, grants for traumatology and surgery of the locomotor system. Printed in Switzerland, 1988
        • Auer JA
        • Watkins JP
        Treatment of radial fractures in adult horses: An analysis of 15 clinical cases.
        Equine Vet J. 1987; 19: 103-110
        • Bukowiecki CF
        • Bramlage LR
        Treatment of a comminuted middle phalangeal fracture in a horse by use of a broad dynamic compression plate.
        J Am Vet Med Assoc. 1989; 194: 1731-1734
        • Cubberly WH
        • Rodeheaver GT
        • Klawitter JJ
        • Edgerton MT
        • Edlich RF
        Glossary of metallurgical terms and engineering tables.
        American Society for metals, Ohio. 1979;
        • Fuchsberger A
        Spiralbohreroptimierung für den Einsatz in der Medizin.
        Z Orthop. 1982; 125: 290-297
        • Gerber H
        • Perren SM
        Evaluation of tissue compatibility in vitro cultures of embryonic bone.
        in: Evaluation of Biomaterials. John Wiley & Sons Ltd., 1980: 307-314
        • Geret V
        • Rahn BA
        • Mathys R
        • Straumann F
        • Perren SM
        A method for testing tissue tolerance for improved quantitative evaluation through reduction of relative motion at the implant-tissue interface.
        in: Evaluation of Biomaterials. John Wiley & Sons Ltd., 1980: 351-359
        • Müller ME
        • Nazarian S
        • Koch P
        • Schatzker J
        The AO classification of fractures of long bones. Springer Verlag Berlin, Heidelberg1990
        • Perren SM
        • Geret V
        • Tepic M
        • Rahn BA
        Quantitative evaluation of biocompatibility of vanadium free titanium alloys.
        Biological and biomechanical performance of biomaterials. 1986; : 397-402
        • Rahn BA
        • Gerber HW
        • Geret V
        • Perren SM
        Assessment of biocompatibility.
        in: World congress on medical physics and biomedical engineering. 1982
        • Schläpfer F
        Testing of drills.
        Internal Report MIB. 1987;
        • Steinemann SG
        Corrosion of surgical implants — “in vitro” and “in vivo” tests.
        in: Review. Institut Straumann Waldenburg, UNI Lausanne, 1989: 1-22
        • Wegst CW
        Stahlschlüssel. Verlag Stahlschlüssel Wegst GmbH, 1989