This paper is only available as a PDF. To read, Please Download here.
Abstract
This paper is intended to provide an overview of the composition, mechanical properties,
biocompatibility, and clinical applications for titanium alloys that are used for
fracture fixation implants. A new class of titanium implant alloys has emerged in
recent years that exhibits a β microstructure and a unique combination of mechanical
properties. Important information regarding notch sensitivity testing and clinical
significance is also discussed. Attributes such as stress corrosion cracking resistance,
fatigue strength, and wear characteristics are also essential for specific clinical
applications, but are beyond the scope of this presentation.
Zusammenfassung
Dieser Artikel soll einen Überblick über die Zusammensetzung, die mechanischen Eigenschaften,
die Biokompatibilität und klinische Anwendungen der Titanlegierungen vermitteln, die
zur Herstellung von Implantaten für die Frakturfixation verwendet werden. In den letzten
Jahren wurde eine neue Klasse von Titanlegierungen für Implantate erarbeitet, welche
über eine β-Gefügestruktur und eine einzigartige Kombination mechanischer Eigenschaften
verfügt. Weitere wichtige Aspekte wie die Testung der Kerbempfindlichkeit und deren
klinische Bedeutung werden ebenfalls diskutiert. Der Widerstand gegen Spannungsrisskorrosion,
die Ermüdungsfestigkeit und das Verschleissverhalten sind für spezifische klinische
Anwendungen ebenfalls wichtige Eigenschaften, auf die im Rahmen dieser Darstellungen
nicht eingegangen werden kann.
Résumé
La composition, les propriétés mécaniques, la biocompatibilité et les applications
cliniques des alliages en titane utilisés pour les implants de fixation des fractures
sont présentées. Une association exceptionnelle de propriétés mécaniques très adaptées
à l'implantation est maintenant possible grâce à la mise au point récente d'une nouvelle
classe d'alliages en titane permettant la fabrication de matériaux à microstructure
β. La discussion porte également sur d'importantes informations concernant les tests
de sensibilité aux encoches et leur signification clinique, à l'exclusion de certains
attributs comme la résistance à la corrosion, le comportement de fatigue et les propriétés
d'usure, caractéristiques essentielles pour des applications cliniques spécifiques.
Resumen
Este estudio pretende ofrecer un panorama general de la composición, propiedades mecánicas,
biocompatibilidad y aplicaciones clínicas de las aleaciones de titanio que se utilizan
para los implantes destinados a la fijación de fracturas. En los últimos años ha surgido
una nueva clase de aleaciones de titanio para implantes que presentan una microestructura
tipo β y una combinación única de propiedades mecánicas. Se discute también información
importante sobre ensayos de sensibilidad al efecto de entalla. Atributos tales como
la resistencia a la fisuración por corrosión bajo tensión, la resistencia a la fatiga
y las características de desgaste son también esenciales para determinadas aplicaciones
clínicas, pero no están dentro del alcance de este estudio.
Keywords
Schlüsselwörter
Mots-clé
Palabras Clave
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to InjuryAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Characterization of Ti-15Mo beta titanium alloy for orthopaedic implant applications.in: Brown SA Lemons JE Medical applications of titanium and its alloys: The material and biological issues. 1996: 60-75 (ASTM STP 1272, ASTM)
- Beta Titanium alloy for surgical implants. Seventh World Conference on Tatanium, San Diego, CA1992
- Roark's Formulas for Stress and Strain. McGraw-Hill, 1989: 33-35 6th Ed.
- Manufacturing processes for semi-finished titanium biomedical alloys.in: Brown SA Lemons JE Medical applications of titanium and its alloys. West Conshohocken, ASTM1996: 17-29
Steinemann SG, Perren SM. Surgical implant and alloy for use in making an implant. U.S. Patent 4,040,129, August 9, 1977.
- Quantitative evaluation of biocompatibility of vanadium free titanium alloys.in: Christel P Meunier A Lee AJC Biological and Biomechanical Performance of Biomaterials. Elsevier Science Publishers, Amsterdam1986: 397
- In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium.J. Bone Joint Surg. [Br]. 1997; 79-B: 311-315
- Sensitivity to titanium - A cause of implant failure.J. Bone Joint Surg. [Br]. 1991; 73-B: 25-28
- Internal fixation and metal allergy - Clinical investigations, immunology and histology of the implant tissue interface. Thieme Medical Publishers, New York1992
- In-vitro corrosion and wear of titanium alloys in the biological environment.Biomaterials. 1996; 17: 2117-2126
- Titanium −6% Aluminium −7% Niobium Implant plant Material.in: Synthes (USA). AO ASIF Booklet, 1993: 9
Article info
Identification
Copyright
© 2000 Published by Elsevier Inc.