      Commercially pure (c.p.) titanium has proven its suitability as an implant material in bone surgery over many years in the fields of osteosynthesis, oral implantology, and in certain applications in joint prosthetics. Excellent biocompatibility and corrosion resistance are outstanding features. Furthermore, c.p. titanium is known for not causing allergic reactions. The different grades of c.p. titanium and their minimum mechanical properties are specified in ISO and ASTM standards for implant materials. Typical mechanical properties are given for AO ASIF implant applications. The properties and clinical performance of c.p. titanium are discussed and compared to those of implant stainless steel and titanium alloys.
      In brief some specific features relating to c.p. titanium implant material are treated, including biocompatibility and soft tissue and bone response and taking into account the effects of implant surface configurations at the same time. In addition, issues are addressed which arise from frequent inquiries from clinics.

      Zusammenfassung

      Kommerziell reines (unlegiertes) Titan hat sich in der Knochenchirurgie seit vielen Jahren als Implantatwerkstoff in den Bereichen von Osteosynthese und Oraler Implantologie, sowie in gewissen Anwendungen der Gelenkprothetik bewährt. Ausgezeichnete Biokompatibilität und Korrosionsresistenz sind besonders hervorragende Eigenschaften. Ausserdem ist Titan dafür bekannt keine Allergien zu verursachen. Die verschiedenen Klassen (grades) von unlegiertem Titan und die entsprechenden minimalen mechanischen Eigenschaftswerte sind in ISO und ASTM Standards spezifiziert. Typische mechanische Eigenschaften für AO Implantatapplikationen sind erwähnt. Die Eigenschaften und das klinische Verhalten von Titan werden diskutiert und es werden Vergleiche zu Implantatstahl und Titanlegierungen gezogen.
      Es werden kurz einige besondere Eigenschaften von Titan-Implantatmaterial dargestellt, einschliesslich Biokompatibilität sowie Weichteil- und Knochenreaktion unter Berücksichtigung von Effekten der Oberflächenkonfiguration. Ferner werden Aspekte angesprochen, zu denen häufig Fragen aus der Klinik gestellt werden.

      Résumé

      Le titane pur de qualité commerciale a fait ses preuves en tant que matériau d'implantation osseuse. Son utilisation au cours des années pour l'ostéosynthèse, l'implantation orale et certains composants de prothèses articulaires en témoignent. Sa grande biocompatibilité et son excellente résistance à la corrosion font du titane un matériau de choix. Un autre avantage du titane pur est l'absence d'une action allergène. Les différentes teneurs en titane pur et les qualités mécaniques minimales correspondantes des matériaux d'implantation sont spécifiées par les normes ISO et ASTM. Nous présentons les propriétés mécaniques typiques des différentes applications des implants AO/ASIF ainsi que les propriétés mécaniques et les performances cliniques des implants en titane pur, en comparaison avec celles des implants en acier inoxydable et en alliages de titane.
      Après un rapide rappel des propriétés des implants en titane en ce qui concerne la biocompatibilité tant au niveau des tissus mous que de l'os ainsi que les effets des configurations de la surface de l'implant, nous adressons des questions souvent posées en pratique clinique.

      Resumen

      El titanio comercialmente puro (c.p.) ha demostrato du adecuación como material para implantes en la cirugía ósea desde hace muchos años en los campos de la osteosíntesis, implantologia maxilofacial y en determinadas aplicaciones de prótesis articulares. Sus características más sobresalientes son su excelente biocompatibilidad y su resistencia a la corrosión. Ademas, el titanio c.p. es conocido por no causar reacciones alérgicas. Las differentes calidades de titanio c.p. están especificadas en las normas ISO y ASTM relativas a materiales para implantes. Se dan las propiedades mecánicas típicas para la aplicación en implantes AO ASIF. Se estudian las propiedades y el comportamiento clínico del titanio c.p. comparándolas con las del acero inoxidable y aleaciones de titanio de calidad implante.
      En resumen, se tratan algunas características específicas del titano c.p. como material para implantes, incluyendo su biocompatibilidad y la respuesta de las partes blandas y del hueso, teniendo en cuenta a la vez los efectos de las distintas configuraciones de la superficie del implante. Además, se abordan los temas que con más frecuencia son consultados por las clínicas.

      Keywords

      Schlüsselwörter

      Mots-clé

      Palabras Clave

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Injury
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Parren SM
        The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP).
        Injury. 1991; 26: 26-30
        • Pohler OEM
        • Straumann F
        Fatigue and corrosion fatigue studies on stainless-steel implant material.
        in: Winter GS Evaluation of Biomaterials. John Wiley & Sons Ltd, Chichester, New York, Brisbane, Toronto, Singapore1980
        • Pohler OEM
        Degradation of metallic orthopedic implants.
        in: Rubin LR Biomaterials in reconstructive surgery. The CV Mosby Comp, St. Louis Toronto London1983: 158-228 (Chap. 15)
        • Arens St
        • Schlegel U
        • Printzen G
        • Ziegler WJ
        • Perren SM
        • Hansis M
        Influence of the materials for fixation implants on local infection. An experimental study of steel versus titanium DC-Plates in rabbits.
        J Bone Joint Surg. [Br]. 1996; 78-B: 647-651
        • Melcher GA
        • Hauke C
        • Metzdorf A
        • et al.
        Infection after intramedullary nailing: An experimental investigation on rabbits.
        Injury. 1996; 27: C23-C26
        • Ungersböck A
        • Geret V
        • Pohler O
        • Schuetz M
        • Wuest W
        Tissue reaction to bone plates made of pure titanium: a prospective, quantitative clinical study.
        J. Mater. Sci. Materials in Medicine. 1995; 6: 223-229
        • Ungersböck A
        • Hunt J
        • Krähenbühl U
        • Perren SM
        Soft tissue reactions to stainless steel/titanium LC-DCP's. A multi-center prospective clinical study.
        Transactions of the 41st Annual meeting of Orthopaedic Research Society. 1995; (Orlando, FL): 577
        • Gerber H.-W.
        • Perren SM
        Evaluation of tissue compatibility of in vitro cultures of embryonic bone.
        in: Winter GD Evaluation of Biomaterials. John Wiley & Sons Ltd, Chichester, New York, Brisbane, Toronto, Singapore1980
        • Ungersböck A
        • Pohler O
        • Perren SM
        Evaluation of the soft tissue interface at titanium implants with different surface treatments: Experimental study on rabbits.
        Bio-Medical Materials and Engineering. 1994; 4: 317-325
        • Ungersböck A
        • Pohler O
        • Perren SM
        Evaluation of soft tissue reactions at the interface of titanium LC-DCP implants with different surface treatments. An experimental sheep study (1994).
        Biomaterials. 1996; 17: 797-806
        • Schröder A
        • Pohler O
        • Sutter F
        Gewebsreaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberfläche.
        Schweiz. Mschr. Zahnheilk. 1976; 86: 713
        • Branemark PJ
        • Hansson BO
        • Adell R
        • et al.
        Osseointegrated implants in the treatment of the edentulous Jaw.
        Scand. J. Plast. Reconstr. Surg. 1997; 11 (Suppl. 16).
        • Steinemann SG
        Compatibility of titanium in soft and hard tissue — The ultimate in osseointegration.
        Proc. Euromat 99. 1999; (München)
        • Buser D
        • Schenk RK
        • Steinemann S
        • Fiorellini JP
        • Fox CH
        • Stich H
        Influence of surface characteristics on bone intergration of implants. A histomorphometric study on miniature pigs.
        J. of Biomed. Mat. Res. 1991; 25: 889-902
        • Pohler OEM
        Swiss screws: concept and experimental work.
        J Oral Implantology. 1986; 12: 338-348