Advertisement
Paper| Volume 22, ISSUE 3, P185-189, May 1991

Is there a mechanical difference between lag screws and double cerclage?

  • T.E. Kanakis
    Correspondence
    Requests for reprints should be addressed to: Dr Theofanis E. Kanakis, Consultant Surgeon, Second Orthopaedic Clinic of Venizelion General Hospital, 143, Leoforos Knossou, Iraklion, 714 09 Crete, Greece.
    Affiliations
    Second Orthopaedic Clinic of Venizelion General Hospital, Iraklion, Crete, Greece
    Search for articles by this author
  • J. Cordey
    Affiliations
    Laboratory for Experimental Surgery, Swiss Research Institute, Davos-Plats, Switzerland
    Search for articles by this author
      This paper is only available as a PDF. To read, Please Download here.

      Abstract

      Comminuted fractures of the long bones present problems of mechanical instability. We therefore used a plate and six screws as the main osteosynthesis combined with supplementary lag screws or cerclage wire. These two supplementary methods were compared. As a model, we used 60 plastic tibias with standard midshaft butterfly fractures. These models, depending on the osteosynthesis applied for the fixation of the butterfly onto the main fracture, were split into three groups of 20 bones. Group A1 with two lag screws, group A2 with two lag screws and two double cerclages, and group A3 with two double cerclages with no lag screws. The models were tested in torque and axial load. The results were:
      • 1.
        1. In torque, group A1 was the most unstable with significant statistical difference from group A2 (P < 0.01) and from A3 (P < 0.05). There was no significant statistical difference between groups A2 and A3.
      • 2.
        2. In axial load, group A3 was stable with significant statistical difference from A2 (P < 0.05). There was no difference between A1 and A3.
      The experiment showed that if the cerclage is used double, anchored at the end of the screws and tensioned, it acts like a spring and is mechanically more stable than lag screws in torque. In axial load, no mechanical difference exists between lag screws and double cerclage.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Injury
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Feyman-Leighton-Sands
        The Feyman Lectures on Physics. Vol II. Addison-Wesley Publishing, New York, London1989: 38
        • Müller E.M.
        • Allgöwer M.
        • Schneider R.
        • et al.
        Manual of Internal Fixation. Springer-Verlag, Berlin, Heidelberg, New York1979
        • Parham F.
        • Martin E.D.
        A new device for the treatment of fractures.
        New Orleans Med. Surg. J. 1913; 21: 451
        • Rentis G.
        • Kanakis Th.
        • Karadimas G.
        Fractures of the shaft of the femur.
        Acta Orthop. Hellenica. 1973; 24: 142
        • Senn N.
        Practical Surgery for the General Practitioner. W. B. Saunders, Philadelphia1901: 531
        • Tscherner H.
        • Haas N.
        • Krettek C.
        Intramedullary nailing combined with cerclage wiring in the treatment of fractures of femoral shaft.
        Clin. Orthop. 1986; 212: 62