Advertisement
Research Article| Volume 13, ISSUE 5, P404-408, March 1982

The slit catheter: a comparison with the wick catheter in the measurement of compartment pressure

      This paper is only available as a PDF. To read, Please Download here.

      Abstract

      The slit catheter, a new instrument for the measurement of compartment pressure, has been compared with the wick catheter in experimental conditions. The two catheters were inserted into the anterior tibial compartments of 8 human legs and controlled external pressures were applied by means of an inflatable limb bag. The mean resting intramuscular pressure of 8.5 ± 6.2 mmHg for the slit and 8.7 mmHg ± 6.2 mmHg for the wick catheter agrees with that of other workers, and the slit catheter records a pressure at all applied external pressures not significantly different from the wick catheter (paired t test).
      The slit catheter provides a simple and inexpensive way of estimating compartment pressure which is as accurate as a method widely used both experimentally and clinically in North America.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Injury
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Holden C.E.A.
        The pathology and prevention of Volkmann's ischaemic contracture.
        J. Bone Joint Surg. 1979; 61B: 296
        • Matsen F.A.
        • Krugmire R.B.
        • King R.V.
        Increased tissue pressure and its effects on muscle oxygenation level and elevated human limbs.
        Clin. Orthop. Rel. Res. 1979; 144: 311
        • Matsen F.A.
        • Winquist R.A.
        • Krugmire R.B.
        Diagnosis and management of compartmental syndromes.
        J. Bone Joint Surg. 1980; 62A: 286
        • Matsen F.A.
        • Mayo K.A.
        • Sheridan G.W.
        • et al.
        Monitoring of intramuscular pressure.
        Surgery. 1976; 79: 702
        • Mubarak S.J.
        • Hargens A.R.
        • Owen C.A.
        • et al.
        The wick catheter technique for measurement of intramuscular pressure.
        J. Bone Joint Surg. 1976; 58A: 1016
        • Mubarak S.J.
        • Owen C.A.
        • Hargens A.R.
        • et al.
        Acute compartment syndromes: diagnosis and treatment with the aid of the wick catheter.
        J. Bone Joint Surg. 1978; 60A: 1091
        • Rorabeck C.H.
        • Macnab I.
        Anterior tibial compartment syndrome complicating fractures of the shaft of tibia.
        J. Bone Joint Surg. 1976; 58A: 549
        • Rorabeck C.H.
        • Castle G.S.P.
        • Lugan J.
        • et al.
        The slit catheter: A new device for measuring intracompartmental pressure.
        in: Am. Coll. Surg. Surgical Forum. 31. 1980: 513
        • Scholander P.F.
        • Hargens A.R.
        • Miller S.L.
        Negative pressure in the interstitial fluid of animals.
        Science. 1968; 161: 321
        • Whitesides T.E.
        • Harvey T.C.
        • Harada H.
        • et al.
        A simple method for tissue pressure determination.
        Arch. Surg. 1975; 110: 1311