Injury
Volume 40, Issue 10 , Pages 1084-1087, October 2009

Reducing radiation exposure in intra-medullary nailing procedures: Intra-medullary endo-transilluminating (iMET)

  • William Chu

      Affiliations

    • Institute of Biomedical Engineering, National Yang-Ming University, 155 Linong Street, Sec. 2, Beitou, Taipei 112, Taiwan, ROC
    • Department of Orthopedics, Cheng Hsin Rehabilitation Medical Center, Beitou, Taipei, Taiwan, ROC
  • ,
  • Jyhpyng Wang

      Affiliations

    • Institute of Atomic and Molecular Sciences, Academia Sinica, P.O. Box 23-166, Taipei, Taiwan, ROC
  • ,
  • Shuenn-Tsong Young

      Affiliations

    • Institute of Biomedical Engineering, National Yang-Ming University, 155 Linong Street, Sec. 2, Beitou, Taipei 112, Taiwan, ROC
  • ,
  • Woei Chyn Chu

      Affiliations

    • Institute of Biomedical Engineering, National Yang-Ming University, 155 Linong Street, Sec. 2, Beitou, Taipei 112, Taiwan, ROC
    • Corresponding Author InformationCorresponding author. Tel.: +886 2 28267025; fax: +886 2 28210847.

Accepted 21 April 2009.

Abstract 

The purpose of the study was to reduce the level of radiation exposure during intra-medullary nailing procedures. A visible light source was inserted into the medullary bone cavity in order to detect the distal interlocking screw holes. The light penetrates out of the bone surface, revealing the position of the screw hole, and this allows the subsequent drilling and placing of the interlocking screw to be free of fluoroscopy. Among the 19 consecutive tibia-fracture patients recruited for this study, no repetition of the drilling procedure or insertion of a transverse interlocking screw was needed. The average time to finish the insertion of one distal interlocking screw was 4.1±1.8min. It was extrapolated that 13–41% of previous radiation exposure levels could be saved. The non-fluoroscopic approach thus decreases the health hazards that the patients are experiencing as well as those of the surgical team who need to perform such intra-medullary nailing operations on a routine basis.

Keywords: Intra-medullary nailing procedure, Free-hand method, Target-aiming device, Distal interlocking, Fluoroscopy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0020-1383(09)00242-3

doi:10.1016/j.injury.2009.04.008

Injury
Volume 40, Issue 10 , Pages 1084-1087, October 2009