Injury
Volume 40, Issue 10 , Pages 1049-1063, October 2009

The clinical and radiological outcomes of the LISS plate for distal femoral fractures: A systematic review

  • T.O. Smith

      Affiliations

    • Institute of Orthopaedics, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UY, Norfolk, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 1603 286990; fax: +44 1603 287369.
  • ,
  • C. Hedges

      Affiliations

    • Physiotherapy Department, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UY, Norfolk, UK
  • ,
  • R. MacNair

      Affiliations

    • Institute of Orthopaedics, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UY, Norfolk, UK
  • ,
  • K. Schankat

      Affiliations

    • Institute of Orthopaedics, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UY, Norfolk, UK
  • ,
  • J.A. Wimhurst

      Affiliations

    • Institute of Orthopaedics, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UY, Norfolk, UK

Accepted 2 January 2009.

Abstract 

Purpose

The purpose of this systematic review was to assess the literature evaluating the clinical and radiological outcomes following less invasive surgical stabilisation system (LISS) fixation of distal femoral fractures (AO 32/33).

Methods

A review of EMBASE, Medline, CINAHL and AMED from their inception to November 2008, sources of grey literature and a pertinent hand search of specialist orthopaedic journals was undertaken.

Results

Twenty-one studies assessing 663 patients with 694 fractures were reviewed. The findings suggest that the LISS system may be an appropriate fixation method for the management of distal femoral fractures. However, there remains a high incidence of loss of reduction (n=134; 19%), delayed or non-union (n=40; 6%) and implant failure (n=38; 5%). On analysis, such complications were largely confined to articles published before 2005, therefore during the infancy of the widespread clinical application of this trauma system. On critical appraisal, the evidence-base remains limited by recruiting small, under-powered sample sizes and poorly accounting for confounding variables such as osteoporosis, diabetes, multi-trauma and fracture classification.

Conclusion

Further study is required to assess the outcomes of LISS fixation in specific patient populations, and to compare the outcome of this fixation method to condylar plates and intrameduallary devices, to determine the optimal management strategy for this complex patient group.

Keywords: Distal femoral fractures, LISS, Minimally invasive operative technique, Systematic review

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0020-1383(09)00003-5

doi:10.1016/j.injury.2009.01.005

Injury
Volume 40, Issue 10 , Pages 1049-1063, October 2009